1st Step: Flash firmware
Control Box |
Filename |
Info |
Software |
AB221A Y1-Y6 |
5134 |
No V900 functions
possible |
Download latest Software (zip folder/include flash
files for all classic control boxes): -19102213 |
AB221A Y7 |
5132 |
|
|
AB321A Y1-Y3 |
5234 |
No V900 functions
possible |
|
AB321A Y4 |
5232 |
|
|
DA321G Y1-Y4 |
5323 |
No V900 functions
possible |
|
DA321G Y5 |
5325 |
|
|
AB425S |
5850 |
Here you will find older versions
(we recommend to use always the latest software):
For this control boxes you have to take care during
the update. If the memory stick is damaged or there is a power off during
update the control box is empty!
In that case you have download software by
IF232-USB cable and EfkaLoader software!
Update by usb memory
stick (FAT/FAT16 format, smaller 4GB):
1.
copy and extract the file to an empty usb memory stick (direct on the root, no subfolder!)
2.
power
off control box
3.
plug
usb memory stick to control box
4.
enter
parameter menu with code number (-link)
5.
Save
actual parameter setting:
a.
Select
parameter .5.1.0.
b.
Press
“E” key, you will see “PUL_”.
c.
Press
“>>” key to see the file name.
d.
Press
“E” key two times to start the operation. You will see “Writ” during operation
and “rdy” when operation has finished.
6.
Download
software:
a.
Select
parameter .5.2.7.
b.
Press
“E” key, you will see “hdL_”.
c.
Press
“>>” key to see the file name.
d.
Select
the correct file by pressing “+” and “-“ key.
e.
Press
“E” key two times to start the
operation. . You will see “read” and then a number counting up. When operation
has finished the control box will restart itself.
7.
Download
parameter setting:
a.
Select
parameter .5.1.1.
b.
Press
“E” key, you will see “PdL_”.
c.
Press
“>>” key to see the file name.
d.
Press
“E” key two times to start the
operation. You will see “read” during operation and “rdy”
when operation has finished.
2nd Step: Compiler program
Info |
Software |
For classic control box
you need additional compiler program! The download includes the source file
(.prc) and the machine code file (.prg) Additional Information: If you have to modify the compiler program or
if you have to include to your own compiler program you need the actual compiler
sys files. Download the file (sys.zip) and extract
to your EFKA Compiler installation folder (Example C:\EFKAComp\Bin\sys) and
replace your old files. Here is a list of all used compiler
resources. |
Download latest Software:
|
Here you will find older
versions (we recommend to use always the latest software):
1.
Extract/copy
the prg file to an empty usb
memory stick (direct on the root, no subfolder!)
2.
power
off control box
3.
plug
usb memory stick to control box
4.
enter
parameter menu with code number (-link)
5.
Download
compiler program:
a.
Select
parameter .5.2.3.
b.
Press
“E” key, you will see “cdL_”.
c.
Press
“>>” key to see the file name.
d.
Press
“E” key two times to start the
operation. You will see “read” during operation and “rdy”
when operation has finished.
6.
After
download restart control box. When you have connected a variocontrol
display V820 you will see following display:
a.
When
BigData enable parameter is NOT set you see the
version number and “BigD”.
b.
When
BigData enable parameter is already set you see the
operator ID login screen “OPID_”.
Control Box |
Software |
AB600A Y1-Y5 AB611A Y5 AB620A Y1-Y6 |
Here you will find older versions
(we recommend to use always the latest software):
-Update Package 18110714
Update by usb memory stick
(here you can use bigger size than 4GB and FAT32 format as well):
1. copy and extract the file to an empty usb
memory stick (direct on the root, no subfolder!)
2. power off control box
3. plug usb memory stick to control
box
4. power on control box
5. Update
will be executed automatically. Wait until you see normal sewing display