Error messages which are send by B18 communication
Common message: %F10001
%: NAK / not acknowledge
F1: adress of control box
0001 or 01: error number. Number is a hexadecimal value has a length of 2 or 4 numbers
Error numbers:
01 PARA_UNKNOWN, unknown parameter number
02 PARA_ERR_MIN, parameter value is smaller than allowed
03 PARA_ERR_MAX, parameter value is bigger than alowed
04 VARIO_AKTIV, change of parameter value not allowed when programming/variocontrol active
05 SEWING, change of parameter value not allowed when sew active
06 UNKNOWN_COMMAND, unknown command
07 DATA_MISSING, no data after '='-sign
08 UNKNOWNHEADER, unknown header ex. 'P', 'T', 'H'
09 TEST_NOT_ENABLED, communication not enabled
0A TEST_UNKNOWN_COMMAND_E, unknown sign after 'E'-sign for test command
0B GET_DATA_NOT_ALOWED, It is not possible to request data
0C SET_DATA_NOT_ALOWED, Setting data not allowed or not possible
0D CODE, wrong code
0E SEPARATOR_EQU, '='-sign is missing
0F SEPARATOR_SEMI, ';'-sign is missing
10 TEACH_PROGNUM_NOTEXIST, Teachin-program number not exist
11 TEACH_NAHTNUM_NOTEXIST, Teachin-sew number not exist
12 PROGNUM_MISSING, Teachin: program number missing
13 NAHTNUM_MISSING, Teachin: sew number missing
14 IS_NOT_AN_FP, FP-Data was send to a non FP control
15 ACESS_DENIEDED, access not allowed, wrong code number
16 DESCRIPT_MISSING, 'X' or 'A'-sign missing
17 PARA_NOT_IN_TEACHINLIST
18 NOT_ENOUGH_SPACE
19 TEACH_DATA_NOTEXIST
1A TO_MUCH_PARAMETER
1B SLAVE_IS_BUSY
1C ERRCSI_UNKNOWN_ELEM_SYSIO